{"product_id":"honeywell-808626","title":"Honeywell 808626 EOL-I End-of-Line Element (EN 54-13 compliant, esserbus)","description":"\u003cdiv\u003e\n\n\u003ch1\u003eHoneywell 808626 EOL-I End-of-Line Device\u003c\/h1\u003e\n\n\u003cp\u003eThe Honeywell ESSER 808626 (Abschlusselement EOL-I) is an end-of-line device that is installed at the last element of the monitored detector zone input; it is used for monitoring detector zone inputs to which conventional fire detectors are connected and for detecting creeping line breaks and short circuits.\u003c\/p\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003e10 kOhm termination\u003c\/h3\u003e\n\n\u003cp\u003eEnd-of-line device with a termination resistance of 10 kOhm ±40 %.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eEN 54-13 compliant\u003c\/h3\u003e\n\n\u003cp\u003eProvides line monitoring (Leitungsüberwachung) in accordance with EN 54-13.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eMaximum line length\u003c\/h3\u003e\n\n\u003cp\u003eThe maximum connection length for the input line is specified as max. 1,000 m.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eDetector quantity limit\u003c\/h3\u003e\n\n\u003cp\u003eMaximum number of detectors per detector zone input: max. 30 standard detectors without ESK, max. 10 standard detectors with ESK.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003eProduct Information\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eAccessory Type\u003c\/strong\u003e : EOL-I end-of-line device (Abschlusselement EOL-I)\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIntended Use\u003c\/strong\u003e : End-of-line device installed at the last element of the monitored detector zone input; for monitoring detector zone inputs to which conventional fire detectors are connected and for detecting creeping line breaks and short circuits.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e : Detects creeping line breaks and short circuits and reports them as faults\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e : Provided by the monitored input line or by the transponder's external power supply\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e : Line monitoring in accordance with EN 54-13\u003c\/p\u003e\n\n\u003cdiv\u003eElectrical Values\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eTermination Resistance\u003c\/strong\u003e : 10 kOhm ±40 %\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePolarity\u003c\/strong\u003e : Attention must be paid to the polarity (+\/-) of the end-of-line devices\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eUnused Inputs\u003c\/strong\u003e : Unused detector zone inputs can be terminated with a 10 kOhm termination resistor or with EOL-I\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMaximum Line Length\u003c\/strong\u003e : max. 1,000 m (input connection line)\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMaximum Number of Detectors\u003c\/strong\u003e : max. 30 standard detectors (without ESK) \/ max. 10 standard detectors (with ESK)\u003c\/p\u003e\n\n\u003cdiv\u003eInstallation\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e : Installed at the last element of the monitored detector zone input\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eArea of Use\u003c\/strong\u003e : Used for detector zone inputs (G1–G4); positioned in the connected periphery (special detector or acoustic\/optical indicators)\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCounterpart for Outputs\u003c\/strong\u003e : Relay outputs are terminated with the EOL-O (808624) end-of-line device\u003c\/p\u003e\n\n\u003cdiv\u003eCompatibility\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatible Products\u003c\/strong\u003e : esserbus alarm transponders \/ esserbus alarm couplers and input\/output modules, e.g. 808623 esserbus alarm couplers 4 IN \/ 2 OUT with isolator (Type 4MG2R); standard (conventional) fire detectors\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatible Accessories\u003c\/strong\u003e : 788600 esserbus transponder housing surface-mounted grey; 788650 surface-mounted white; 788601 flush-mounted grey; 788651 flush-mounted white; 788605 mounting kit; 788602 C-rail; 788603 module housing\u003c\/p\u003e\n\n\u003cdiv\u003ePhysical\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e : esserbus transponder housing style\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eColor\u003c\/strong\u003e : Grey and white housing options available as accessories\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e : 0.01 kg (approx. 10 g)\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":58234409386367,"sku":"808626","price":0.0,"currency_code":"TRY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/0805\/7471\/files\/808626_1.jpg?v=1787227936","url":"https:\/\/www.favtechnology.com\/en\/products\/honeywell-808626","provider":"FAV Technology","version":"1.0","type":"link"}