{"title":"Fire Alarm Control Panels","description":"\u003cp\u003eFire Panels\u003c\/p\u003e","products":[{"product_id":"honeywell-786020-on-panel-turkce","title":"Honeywell 786020 Turkish Operation Module Front Panel","description":"\u003cdiv\u003e\n\n\u003ch1\u003eHoneywell 786020\u003c\/h1\u003e\n\n\u003cp\u003eThe Honeywell ESSER 786020 Turkish operating module front panel is a front panel with Turkish language labels for IQ8Control C and IQ8Control M addressable fire alarm control panels; it is not a standalone end-user product and is used in conjunction with the panel operating module.\u003c\/p\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eTurkish Labeling\u003c\/h3\u003e\n\n\u003cp\u003eFront panel with Turkish language labels for IQ8Control C and IQ8Control M addressable fire alarm control panels.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eLED Indicators\u003c\/h3\u003e\n\n\u003cp\u003eFeatures indicators for Fire (FEUER), Pre-alarm (VORALARM), Fault (STÖRUNG), Operation (Betrieb), Emergency operation (Notbetrieb), Power supply (Stromversorgung EV), Delayed (Verzögert), Investigate (Erkunden), Control (Steuerung AE), Main alarm \/ transmission device (Hauptmelder ÜE), Call Fire Department (Feuerwehr rufen), Test mode (Testbetrieb), and Disablement (Abschaltung).\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eDisplay Structure\u003c\/h3\u003e\n\n\u003cp\u003e4-line standard display; supports 8 lines and 40 characters per line in operational status.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eControl Elements\u003c\/h3\u003e\n\n\u003cp\u003eIncludes F1–F4 function keys, cursor (direction) keys, and a numeric keypad.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003eGeneral Features\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e : 786020\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAccessory Type\u003c\/strong\u003e : Operating module front panel \/ front bezel\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePurpose of Use\u003c\/strong\u003e : Front panel with Turkish language labels for IQ8Control C and IQ8Control M addressable fire alarm control panels; not a standalone end-user product, used in conjunction with the panel operating module\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatible Products\u003c\/strong\u003e : ESSER IQ8Control C; IQ8Control M\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLanguage Variants (order numbers)\u003c\/strong\u003e : 786001 German, 786002 English, 786010 Russian, 786020 Turkish, 786100 Neutral\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e : Novar GmbH, a Honeywell Company, Neuss, Germany\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eUser Manual Reference\u003c\/strong\u003e : 798950\u003c\/p\u003e\n\n\u003cdiv\u003eDisplay and Control\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eDisplay - standard number of lines\u003c\/strong\u003e : 4\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDisplay - number of lines in operational status\u003c\/strong\u003e : 8\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDisplay - characters per line\u003c\/strong\u003e : 40\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKeys\u003c\/strong\u003e : F1–F4 function keys; cursor (direction) keys; numeric keypad\u003c\/p\u003e\n\n\u003cdiv\u003eElectrical\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eStandby Current\u003c\/strong\u003e : Approximately 45 mA\u003c\/p\u003e\n\n\u003cdiv\u003eInstallation\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e : Panel front panel \/ front bezel\u003c\/p\u003e\n\n\u003cdiv\u003eStandards\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e : EN 54-2:1997\/A1:2006\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCertificates (VdS)\u003c\/strong\u003e : G 299044; G 205129\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":57594594165119,"sku":"786020","price":0.0,"currency_code":"TRY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/0805\/7471\/files\/786020_1.jpg?v=1787227937"},{"product_id":"honeywell-804382-d0-analog-loop-modulu-powered","title":"Honeywell 804382.D0 Loop Module esserbus-PLus (Powered Loop, IQ8Control \/ FlexES Control)","description":"\u003cdiv\u003e\n\n\u003ch1\u003eHoneywell 804382.D0\u003c\/h1\u003e\n\n\u003cp\u003eThe Honeywell 804382.D0 is a plug-in, addressable analog loop module in micromodule format, providing esserbus-PLus powered operating mode, and is used by being installed in a fire alarm control panel.\u003c\/p\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003e1 Loop and Max. 127 Devices\u003c\/h3\u003e\n\n\u003cp\u003eSupports 1 loop line and max. 127 bus devices\/subscribers.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eProtocol Support\u003c\/h3\u003e\n\n\u003cp\u003eSupports esserbus and esserbus-PLus protocols and enables esserbus-PLus powered loop mode.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eElectrical Requirements\u003c\/h3\u003e\n\n\u003cp\u003eLoop line voltage is 42 V; operating voltage is 24 V DC \/ 12 V DC, and standby current is approximately 60 mA.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eInstallation and Connection\u003c\/h3\u003e\n\n\u003cp\u003eIt is plug-in mounted into the panel's micromodule slot and connected to the base module with a 64-pin connector.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003eGeneral Features\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e : 804382.D0\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e : Analog addressable loop micromodule\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNumber of Loops\u003c\/strong\u003e : 1 loop circuit\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMax. Bus Devices\u003c\/strong\u003e : 127 (the number of esserbus-PLus devices should be planned according to the load factor)\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eBus \/ Protocol\u003c\/strong\u003e : esserbus and esserbus-PLus (powered loop)\u003c\/p\u003e\n\n\u003cdiv\u003eElectrical\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e : 24 V DC \/ 12 V DC\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eStandby Current\u003c\/strong\u003e : Approximately 60 mA\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLoop Line Voltage\u003c\/strong\u003e : 42 V\u003c\/p\u003e\n\n\u003cdiv\u003eLine and Cabling\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eMax. Line Length\u003c\/strong\u003e : 3500 m\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRecommended Cable and Conductor Cross-Section\u003c\/strong\u003e : I-Y(St)Y n × 2 × 0.8 mm (conductor diameter 0.8 mm) or fire alarm cable\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePanel Connection\u003c\/strong\u003e : Connected to the base module with a 64-pin connector (64-polige Steckerleiste)\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLoop Monitoring\u003c\/strong\u003e : Bi-directional loop interrogation via K1 and K2 isolation relays\u003c\/p\u003e\n\n\u003cdiv\u003eCompatibility\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eSupported Devices\u003c\/strong\u003e : Series 9200 process analog detectors, IQ8Quad intelligent fire detectors, esserbus couplers, addressable sounders and esserbus-PLus connected signal\/siren sockets\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatible Panels\u003c\/strong\u003e : ESSER IQ8Control C, IQ8Control M and FlexES Control\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRelated Part\u003c\/strong\u003e : 772478 (1 expansion module with additional micromodule slot)\u003c\/p\u003e\n\n\u003cdiv\u003ePhysical\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e : 0.2 kg\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e : Panel's micromodule slot (plug-in)\u003c\/p\u003e\n\n\u003cdiv\u003eCertifications\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eEN 54\u003c\/strong\u003e : EN 54-2:1997\/A1:2006\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Approvals\u003c\/strong\u003e : VdS approvals G 299044 and G 205129\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":57594594328959,"sku":"804382.D0","price":0.0,"currency_code":"TRY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/0805\/7471\/files\/804382_D0_1.jpg?v=1787230207"},{"product_id":"honeywell-784840-10-essernet-modulu-62-5kbd","title":"Honeywell 784840.10 essernet Network Module 62.5 kBd (IQ8Control)","description":"\u003cdiv\u003e\n\n\u003ch1\u003eHoneywell 784840.10\u003c\/h1\u003e\n\n\u003cp\u003eThe essernet module is the network interface card that connects IQ8Control fire control panels to the essernet network; it allows multiple fire panels to be operated in a networked manner by connecting them in a ring\/loop structure, and data is exchanged via a token-passing protocol.\u003c\/p\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003e62.5 kBd Network Communication\u003c\/h3\u003e\n\n\u003cp\u003eData transmission is performed at 62.5 kBd.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eUp to 16 Participants\u003c\/h3\u003e\n\n\u003cp\u003eA maximum of 16 participants can be connected to the network.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eRing Topology\u003c\/h3\u003e\n\n\u003cp\u003eProvides interruption and short-circuit tolerance with ring topology.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eOperating Voltage\u003c\/h3\u003e\n\n\u003cp\u003e12 V DC and 24 V DC are supported; standby current at 12 V DC is approximately 150 mA.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003eNetwork\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eTransmission rate\u003c\/strong\u003e : 62.5 kBd\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMaximum network participants\u003c\/strong\u003e : 16\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTransmission protocol\u003c\/strong\u003e : Token-passing protocol, similar to DIN 19245-1 (Profibus) loop technology\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNetwork topology\u003c\/strong\u003e : Ring, tolerant to interruption and short circuit\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCable type\u003c\/strong\u003e : Telecommunication cable I-Y(St)Y n × 2 × 0.8 mm\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMaximum cable length\u003c\/strong\u003e : 1000 m\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOptical fiber connection\u003c\/strong\u003e : Optionally available\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRedundant data connection\u003c\/strong\u003e : Requires at least 2 DOM and 2 SEI\u003c\/p\u003e\n\n\u003cdiv\u003eElectrical\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e : 12 V DC and 24 V DC\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eStandby current (12 V DC)\u003c\/strong\u003e : Approx. 150 mA\u003c\/p\u003e\n\n\u003cdiv\u003eCompatibility\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e : IQ8Control fire alarm panels\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e : EN 54\u003c\/p\u003e\n\n\u003cdiv\u003eOrdering Information\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e : 784840.10\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":57594594361727,"sku":"784840.10","price":0.0,"currency_code":"TRY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/0805\/7471\/files\/784840_10_1.jpg?v=1787230604"},{"product_id":"honeywell-772478-1mm-slotlu-genisleme-modulu","title":"Honeywell 772478 Extension Module 1 Additional Micromodule Slot IQ8Control Compatible","description":"\u003cdiv\u003e\n\n\u003ch1\u003eHoneywell 772478\u003c\/h1\u003e\n\n\u003cp\u003eThe 772478 expansion module is inserted into the interface board of the IQ8Control C \/ IQ8Control M addressable fire alarm control panel; it provides 1 additional micromodule slot and can only be used in system connector 1 (Systemstecker 1) position of the interface board. The inserted micromodules must be configured to the desired function with jumpers and DIP switches and programmed according to the panel configuration. The operating voltage is supplied via the panel's internal power supply module; the standby current is approximately 5 mA when no micromodule is inserted.\u003c\/p\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003e1 Additional Micromodule Slot\u003c\/h3\u003e\n\n\u003cp\u003eProvides 1 additional micromodule slot when inserted into the interface board.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eIQ8Control C\/M Compatible\u003c\/h3\u003e\n\n\u003cp\u003eUsed in the interface board of IQ8Control C and IQ8Control M addressable control panels.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eLow Standby Current\u003c\/h3\u003e\n\n\u003cp\u003eThe standby current is approximately 5 mA when no micromodule is inserted.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eVdS Approved\u003c\/h3\u003e\n\n\u003cp\u003eThe product is VdS approved and indicated as a discontinued model in the manufacturer's catalog.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003eProduct Information\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e : 772478\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAccessory Type\u003c\/strong\u003e : Expansion module (Erweiterungsmodul)\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePurpose of Use\u003c\/strong\u003e : Provides 1 additional micromodule slot when inserted into the IQ8Control C\/M interface board\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAdditional Micromodule Slots\u003c\/strong\u003e : 1\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatible Products\u003c\/strong\u003e : IQ8Control C \/ IQ8Control M addressable fire alarm control panels\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCertificates\u003c\/strong\u003e : VdS approved\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProduct Status\u003c\/strong\u003e : Discontinued model (Auslaufmodell)\u003c\/p\u003e\n\n\u003cdiv\u003eInstallation\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e : Mounted on the panel's interface board, in system connector 1 (Systemstecker 1) position\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eArea of Use\u003c\/strong\u003e : IQ8Control C\/M addressable fire alarm control panel interface board\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMounting Restriction\u003c\/strong\u003e : Only one module (772477 \/ 772478 \/ 772479) can be installed on the interface board at the same time\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIncompatible Modules\u003c\/strong\u003e : Series 01 peripherals and expansion modules (772418, 772419, 772420, 772421) cannot be installed in IQ8Control C\/M\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatible Micromodules\u003c\/strong\u003e : 804382.D0 micromodule esserbus-PLus; 784840.10 micromodule essernet 62.5 kBd; 784842.F0 micromodule serial interface RS232\/TTY\u003c\/p\u003e\n\n\u003cdiv\u003eElectrical\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eStandby Current\u003c\/strong\u003e : approx. 5 mA (when no micromodule is inserted)\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e : Supplied via the panel's internal power supply module\u003c\/p\u003e\n\n\u003cdiv\u003ePhysical\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e : 0.2 kg\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOperating Temperature (inside IQ8Control C\/M panel)\u003c\/strong\u003e : -5 °C ... +45 °C\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eStorage Temperature (inside IQ8Control C\/M panel)\u003c\/strong\u003e : -5 °C ... +50 °C\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eEnvironmental Class\u003c\/strong\u003e : Class 3k5 (IEC 721-3-3:1994)\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e : I (DIN EN 60950)\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":57594594525567,"sku":"772478","price":0.0,"currency_code":"TRY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/0805\/7471\/files\/772478_1.jpg?v=1787227909"},{"product_id":"honeywell-808003-facp-iq8control-c","title":"Honeywell IQ8Control C 808003 Modular Addressable Fire Alarm Control Panel","description":"\u003cdiv\u003e\n\n\u003ch1\u003eHoneywell IQ8Control C 808003\u003c\/h1\u003e\n\n\u003cp\u003eThe IQ8Control C is a modular addressable fire alarm control panel. The basic unit is equipped with an enclosure including a standard back panel and a front frame for the operating panel surfaces, an interface board, a power supply module, and system software, and accepts micromodules and esserbus analog loop modules.\u003c\/p\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eModular addressable design\u003c\/h3\u003e\n\n\u003cp\u003eIQ8Control C offers support for intelligent addressable systems in a modular design.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eExpansion support\u003c\/h3\u003e\n\n\u003cp\u003eMax. two micromodules and max. two esserbus analog loop modules can be installed.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eLoop capacities\u003c\/h3\u003e\n\n\u003cp\u003eEach esserbus loop supports max. 127 esserbus devices (fire detectors and\/or manual call points) and max. 32 transponders.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eScope of delivery\u003c\/h3\u003e\n\n\u003cp\u003eEnclosure, standard back panel and front frame, interface board, power supply module, and system software are included in the delivery; the operating front must be ordered separately.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003eCapacity \/ Expansion\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eMicromodule\u003c\/strong\u003e : Max. two micromodules\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eEsserbus loop module\u003c\/strong\u003e : Max. two esserbus analog loop modules\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDevice capacity\u003c\/strong\u003e : Max. 127 esserbus devices per loop\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTransponder\u003c\/strong\u003e : Max. 32 esserbus transponders per loop\u003c\/p\u003e\n\n\u003cdiv\u003eElectrical\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e : 230 V AC\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e : 12 V DC\u003c\/p\u003e\n\n\u003cdiv\u003ePower \/ Battery\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e : 2 × 12 Ah; 2 × 24 Ah in expansion enclosure\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuiescent current\u003c\/strong\u003e : Approx. 215 mA (basic configuration, without operating unit)\u003c\/p\u003e\n\n\u003cdiv\u003ePhysical\u003c\/div\u003e\n\u003c!--nl--\"\u003e\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e : W 450 mm × H 320 mm × D 185 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e : Approx. 6.5 kg\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e : ABS, 10% glass fiber reinforced\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eColor\u003c\/strong\u003e : Gray, similar to Pantone 538\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProtection type\u003c\/strong\u003e : IP 30\u003c\/p\u003e\n\n\u003cdiv\u003eEnvironmental\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e : -5 °C ... +45 °C\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e : -5 °C ... +50 °C\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAir humidity\u003c\/strong\u003e : \u0026lt; 95 %\u003c\/p\u003e\n\n\u003cdiv\u003eStandards\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e : VdS, BOSEC; revision according to EN 54\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":57594594558335,"sku":"808003","price":0.0,"currency_code":"TRY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/0805\/7471\/files\/808003_1.jpg?v=1787228596"},{"product_id":"honeywell-fx808340-essernet-modulu-62-5kbd","title":"Honeywell FX808340 62.5 kBd essernet Network Card FlexES Control","description":"\u003cdiv\u003e\n\n\u003ch1\u003eHoneywell FX808340\u003c\/h1\u003e\n\n\u003cp\u003eThe FX808340 essernet network card\/module is designed for integration of the FlexES Control fire alarm control panel into the essernet network and supports 62.5 kBd data transmission in a ring topology with token passing protocol (DIN 19245-1 \/ Profibus-like).\u003c\/p\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003e62.5 kBd Data Rate\u003c\/h3\u003e\n\n\u003cp\u003eProvides 62.5 kBd data transmission via the essernet network.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003ePlastic Housing with LED Indicator\u003c\/h3\u003e\n\n\u003cp\u003eFeatures a plastic protective housing and LED indicators for operational status.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eHot Swappable and Automatic Recognition\u003c\/h3\u003e\n\n\u003cp\u003eSupports hot-swapping with automatic module recognition.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eScrewless Mechanical Lock\u003c\/h3\u003e\n\n\u003cp\u003eEnsures mechanical locking without screws.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003eGeneral Features\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e : FX808340\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e : essernet network card\/module, 62.5 kBd, for FlexES Control\u003c\/p\u003e\n\n\u003cdiv\u003eNetwork\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e : 62.5 kBd\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e : Token passing protocol (DIN 19245-1 \/ Profibus-like), ring topology\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNumber of Network Participants\u003c\/strong\u003e : Max. 16 network devices\u003c\/p\u003e\n\n\u003cdiv\u003eConnection\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eConnection \/ Interface\u003c\/strong\u003e : FOC (fiber optic connector) for FM approved systems\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e : Telecommunication cable I-Y (St) Y n x 2 x 0.8 mm or similar\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMaximum Cable Distance\u003c\/strong\u003e : 1000 m\u003c\/p\u003e\n\n\u003cdiv\u003eElectrical\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e : 24 V DC\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIdle Current Consumption\u003c\/strong\u003e : ≈ 37 mA\u003c\/p\u003e\n\n\u003cdiv\u003ePhysical\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e : W 27 mm × H 93 mm × D 112 mm\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e : ≈ 100 g\u003c\/p\u003e\n\n\u003cdiv\u003eApprovals\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e : VdS, FM\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":57594595180927,"sku":"FX808340","price":0.0,"currency_code":"TRY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/0805\/7471\/files\/FX808340_1.jpg?v=1787228603"},{"product_id":"honeywell-784850-serial-essernet-interface-2","title":"Honeywell 784850 Series essernet Interface SEI2 (TTY \/ RS232 \/ RS485)","description":"\u003cdiv\u003e\n\n\u003ch1\u003eHoneywell 784850\u003c\/h1\u003e\n\n\u003cp\u003eThe serial essernet Interface SEI2 enables bidirectional data transmission and remote control between ESSER fire alarm control panels (800x series, IQ8Control, FlexES Control) and external EDP-compatible systems via TTY or RS232\/RS485.\u003c\/p\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eConnection Interfaces\u003c\/h3\u003e\n\n\u003cp\u003eSupports TTY, RS232, and RS485 connections.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\n\u003cp\u003eCompatible with ESSER 800x series, IQ8Control, and FlexES Control panels.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003ePower Consumption\u003c\/h3\u003e\n\n\u003cp\u003eApprox. 30 mA at 12 V DC without module, approx. 130 mA with module; approx. 20 mA at 24 V DC without module, approx. 70 mA with module.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003ePhysical Characteristics\u003c\/h3\u003e\n\n\u003cp\u003eHousing made of ABS plastic, 10% glass fiber reinforced, dimensions W 270 mm × H 221 mm × D 75 mm, and IP 30 protection rating.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003eGeneral Features\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: 784850\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e: Serial essernet Interface SEI2; connects ESSER panels to external EDP systems, provides bidirectional data transmission and remote control.\u003c\/p\u003e\n\n\u003cdiv\u003eTechnical Details\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 10.5 - 30 V DC\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption (without module)\u003c\/strong\u003e: Approx. 30 mA at 12 V DC; approx. 20 mA at 24 V DC\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption (with essernet module)\u003c\/strong\u003e: Approx. 130 mA at 12 V DC; approx. 70 mA at 24 V DC\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e: positive safety only\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: W 270 mm × H 221 mm × D 75 mm\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e: ABS plastic, 10% glass fiber reinforced (V-0)\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eColor\u003c\/strong\u003e: Grey (similar to Pantone 538)\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e: IP 30\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e: Screw terminals; FO connector\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -5 °C ~ +50 °C\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -10 °C ~ +50 °C\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e: Class 3k5, DIN EN 60721-3-3\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eInterface and Compatibility\u003c\/strong\u003e: TTY, RS232, RS485; optional essernet module integration 62.5 kBd or 500 kBd; compatible panels ESSER 800x series, IQ8Control, FlexES Control\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eScope of Delivery\u003c\/strong\u003e: Basic module in housing\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAccessories to be Ordered Separately\u003c\/strong\u003e: 784870 M4-RS232-iso, 784871 M4-RS485-iso, 784872 M4-TTY, FX808340 essernet module 62.5 kBd, FX808341 essernet module 500 kBd\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":57594605896063,"sku":"784850","price":0.0,"currency_code":"TRY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/0805\/7471\/files\/784850_1.jpg?v=1787230989"},{"product_id":"honeywell-784870-m4-rs232-iso-interface-module","title":"Honeywell M4-RS232-iso 784870 RS232 Module with Galvanic Isolation","description":"\u003cdiv\u003e\n\n\u003ch1\u003eHoneywell 784870 M4-RS232-iso\u003c\/h1\u003e\n\n\u003cp\u003e784870 M4-RS232-iso is a plug-in compact interface module belonging to the System 4000 M4 module platform, providing a galvanically isolated RS232 serial interface; it features a connector design that prevents reverse\/incorrect insertion.\u003c\/p\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eGalvanically isolated RS232\u003c\/h3\u003e\n\n\u003cp\u003eProvides a galvanically isolated RS232 serial interface.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003ePlug-in compact module\u003c\/h3\u003e\n\n\u003cp\u003eCompact plug-in design compatible with the System 4000 M4 module platform.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eConnector preventing reverse insertion\u003c\/h3\u003e\n\n\u003cp\u003eThe connector design prevents reverse or incorrect insertion.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003eSEI2 and ESSER compatibility\u003c\/h3\u003e\n\n\u003cp\u003eCompatible for use with Serial essernet Interface SEI2 (Part No. 784850); compatible with ESSER ES Line, Compact and FlexES Control panels.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003eInput\/Output\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e : M4-RS232-iso\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e : Interface module (Schnittstellenmodul), plug-in compact module\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e : RS232, galvanically isolated\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e : Design preventing reverse\/incorrect insertion\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatible Interface\u003c\/strong\u003e : Serial essernet Interface SEI2, Part No. 784850\u003c\/p\u003e\n\n\u003cdiv\u003eElectrical\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e : 3.3 V DC\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e : max. 20 mA\u003c\/p\u003e\n\n\u003cdiv\u003eGeneral\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e : W 27 mm × H 53 mm × D 15 mm\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e : Compact plug-in module\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eModule Platform\u003c\/strong\u003e : System 4000, M4 module series\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatible Panels\u003c\/strong\u003e : ESSER ES Line, Compact and FlexES Control fire alarm panels\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatible Panel Series\u003c\/strong\u003e : ESSER 800x series panels and IQ8Control\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSupported Protocol Context\u003c\/strong\u003e : Connection to external systems supporting EDP (ESSER Data Protocol) via SEI2\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAlternative M4 Interface Modules\u003c\/strong\u003e : 784871 M4-RS485-iso; 784872 M4-TTY\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRelated essernet Modules\u003c\/strong\u003e : FX808340 essernet module 62.5 kBd; FX808341 essernet module 500 kBd\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProduct Status\u003c\/strong\u003e : Discontinued product (Auslaufprodukt)\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":57594605928831,"sku":"784870","price":0.0,"currency_code":"TRY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/0805\/7471\/files\/784870_1.jpg?v=1787227689"}],"url":"https:\/\/www.favtechnology.com\/en\/collections\/yangin-panelleri.oembed","provider":"FAV Technology","version":"1.0","type":"link"}